Table

21. EN_OUT1–EN_OUT12 Configuration (continued)

REGISTER ADDRESS

FLASH ADDRESS

BIT RANGE

DESCRIPTION

31h

231h

[1:0]

EN_OUT5 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[3:2]

EN_OUT6 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[5:4]

EN_OUT7 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[7:6]

EN_OUT8 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

32h (MAX16065 Only)

232h

[1:0]

EN_OUT9 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[3:2]

EN_OUT10 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[5:4]

EN_OUT11 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull

[7:6]

EN_OUT12 Configuration:
00 = Active-low, open drain
01 = Active-high, open drain
10 = Active-low, push-pull
11 = Active-high, push-pull