AT8xC51SND1C

4109E–8051–06/03

Table 131. Serial Bit Rates

Notes:

1. These frequencies are achieved in X1 mode, F

PER

= F

OSC

÷

2.

2. These frequencies are achieved in X2 mode, F

PER

= F

OSC

.

Data Transfer

The Clock Polarity bit (CPOL in SPCON) defines the default SCK line level in idle
state

(1)

while the Clock Phase bit (CPHA in SPCON) defines the edges on which the

input data are sampled and the edges on which the output data are shifted (see
Figure 115 and Figure 116). The SI signal is output from the selected slave and the SO
signal is the output from the master. The AT8xC51SND1C captures data from the SI line
while the selected slave captures data from the SO line.

For simplicity, Figure 115 and Figure 116 depict the SPI waveforms in idealized form
and do not provide precise timing information. For timing parameters refer to the Section
“AC Characteristics”.

Note:

1. When the peripheral is disabled (SPEN = 0), default SCK line is high level.

Figure 115. Data Transmission Format (CPHA = 0)

SPR2

SPR1

SPR0

Bit Rate (kHz) Vs F

PER

F

PER

Divider

6 MHz

(1)

8 MHz

(1)

10 MHz

(1)

12 MHz

(2)

16 MHz

(2)

20 MHz

(2)

0

0

0

3000

4000

5000

6000

8000

10000

2

0

0

1

1500

2000

2500

3000

4000

5000

4

0

1

0

750

1000

1250

1500

2000

2500

8

0

1

1

375

500

625

750

1000

1250

16

1

0

0

187.5

250

312.5

375

500

625

32

1

0

1

93.75

125

156.25

187.5

250

312.5

64

1

1

0

46.875

62.5

78.125

93.75

125

156.25

128

1

1

1

6000

8000

10000

12000

16000

20000

1

1

2

3

4

5

6

7

8

MSB

bit 1

LSB

bit 2

bit 4

bit 3

bit 6

bit 5

bit 1

bit 2

bit 4

bit 3

bit 6

bit 5

MSB

LSB

MOSI (From Master)

MISO (From Slave)

SCK (CPOL = 1)

SCK (CPOL = 0)

SPEN (Internal)

SCK Cycle Number

SS (to slave)

Capture point

Advertising