R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Select Service Manual User Manual

Page 22

Advertising
background image

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319

22/46

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

P1.1.4

Minimum Freq

0.00

Max freq

Hz

The set minimum operating frequency.

P1.1.5

Maximum Freq

Min freq 120.00

Hz

The maximum frequency may not be higher than the motor nominal frequency for listed
motors.

P1.1.6

Reverse Plugging

50

100

%

See Chapter "Reverse plugging"

P1.1.7

Stop Function

0

1

Stopping mode selection
0 = Brake
1 = Ramping, default
Ramping: When the drive command is switched off the motion is stopped according to
the set deceleration ramp.
Brake: When the drive command is switched off the motor current is cut off, then the
motion is stopped by the mechanical brake.

P1.1.8

MSFreq2/Slowdown

0

100

Hz

Slowdown frequency and Multistep frequency2

P1.1.9

Multistep Freq 3

0

100

Hz

3

rd

preset speed.

P1.1.10 Multistep Freq 4

0

100

Hz

4

th

preset speed.

P1.1.11 Input set

0

7

Control mode selection, see Chapter "control methods"
0 = MS2 (stop-limit)
1 = MS2/MS3 (slow-limit)
2 = EP2 (stop-limit)
3 = EP2 (slow-limit)
4 = EP3
5 = MS4
6 = MS5
7 = AU (Ain)

G1.2 Motor Parameters

Code

Name

Min

Max

Unit Description

P1.2.1

Motor Nominal
Voltage

200

500

V

Nominal motor voltage Un from motor nameplate.

P1.2.2

Motor Selection

0

9

0 = Not Used
1 = Free Travel
2 = MF06MA100
3 = MF06MA200
4 = MF06LA100
5 = MF06LA200 (MF06LA200, 0.45kW/400V; 0.55kW/460V)
6 = MF06LA20P (MF06LA200, 0.65kW/400V; 0.75kW/460V)
7 = Not Used
8 = Not Used
9 = Free Hoist

Note1: when one of listed motors is selected, Parameters group G1.2.4, G1.2.5 and
G1.2.6 are not viewable. Parameters group G1.2.4, G1.2.5 can be viewed after P1.2.2 is
set back to 1 ‘’free travel’’

P1.2.3

Number of Motors

0

10

pcs

The parameter is not active if value 0,1 or 9 in P1.2.2 is selected

G1.2.4 Motor Nominal Values, see note1
Code

Name

Min

Max

Unit Description

P1.2.4.1 Motor Nominal

Frequency

0.00

120.00

Hz

Nominal motor frequency (fn) from motor nameplate

P1.2.4.2 Motor Nominal current 0.0

A

Disc brake motors:
Number of motors * In (Motor nominal current)

Compact brake motors:
Number of motors * In or
Number of motors * 2,3A, if In<2,3A

DC-current during starting = Motor Nominal current P1.2.4.2. * Start Current P1.2.6.1
DC-current during stoping = Motor Nominal current P1.2.4.2.

Advertising