2 general, 1 technical data – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Select Service Manual User Manual

Page 4

Advertising
background image

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319

4/46

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

2 GENERAL

2.1 Technical

data

Power class

002F 003F 004F 005F 007F 011F 015F 018F 022F

Power

(kVA)

at

400V

3.5 5.5 7.0 9.0 13 17 22 29 33

Output

current

In

(A)

5.0 8 10 13 18 24 32 42 48

Max.

current

1min

(A)

7.6 12 15 20 27 36 48 63 72

Overload ability

1.5 x In, 1min/10min

Max. output voltage

Equals to supply voltage

Supply

Supply voltage

380-500Vac

Allowable voltage fluctuation

+/- 10%

Nominal supply frequency

50/60Hz +/- 5%

Signal input levels

Digital controls

S1, S2, DID3, DID4, DID5: 42 … 240Vac; 15mA

Control features

Control method

Open loop vector control

Frequency control range

0 ... 250Hz

Frequency command

Electronic potentiometer, 2-5-step controller or 0 … 10V analog signal

Limit switch functions

Slowdown and stop limit inputs for both directions

Speed control range

s

N

... 100% (s

N

= motor nominal slip)

Speed accuracy

1% of nominal speed at speed range 10 ... 100%

1/3 of motor nominal slip at speed below 10%

Braking torque

150%

Protections

Motor overload protection

Thermistor or Klixon thermostat based temperature measurement

Overload protection

Fault is detected if the current momentarily exceeds 280% of rated current

Undervoltage / blown fuse

Fault is detected if DC voltage drops below 333V

Overvoltage protection

Fault is detected if DC voltage exceeds 911V

Momentary power loss

Immediate fault stop

Inverter overtemperature

Temperature sensor on the heat sink

Mechanical brake

Circuit breaker (from 007 upward)

Ground fault

Provided by electronic circuitry

Ambient conditions

Ambient temperature

-10

°C ... +50°C (14°F ... 122°F) for ED≤40%

Storage temperature

-40

°C ... +70°C (-31°F ... 158°F) dry

Humidity <95%RH

(no

condensation)

Altitude

Maximum 1000m at In. Above 1000m: In reduces 1% per each 100m.

Above 3000m: consult factory.

Vibration

Operation: maximum displacement amplitude 3mm at 2-9Hz.

Maximum acceleration amplitude 0.5g (5m/s²) at 9-200Hz

Conforms to LV and EMC directives.

Advertising