Dipswitch, Pairing button – SENA Parani-SD1100 User Manual

Page 14

Advertising
background image

14

3.6. Dipswitch


With the combination of 4 slot dipswitches, RS422/485 select, Termination resistor on/off, RS485 echo
on/off and UART configuration can be set.

Figure 3-1 The Parani-SD1100 Dipswitch


Table 3-4 RS422/485 Select by Dipswitch

RS422 RS485

422

485

Table 3-5 Termination Resistor Select by Dipswitch

Termination R Off On

Off

On

Table 3-6 RS485 Echo Control by Dipswitch

RS485 Echo Off On

Off

On


Table 3-7 UATR Configuration by Dipswitch

9600-8N1 SW Config

9600-8N1

SW Config

* Note 1: You can set the Parani-SD1100 to of the default UART configuration of 9600-8N1 by way of
the Dipswitch. If you want to use other than the default UART configuration, please configure the
dipswitch to SW Config setting and use ParaniWIN or AT commands. Please refer to 3.9. ParaniWIN
and Appendix B.3.4. AT+UARTCONFIG, Baudrate,Paraty,Stopbit.

*Note 2: If you use 485 Echo option when you use both master and slave units as SD1100, then it may
cause data loss or conflict with various control messages such as AT response messages, i.e. OK,
ERROR, CONNECT, DISCONNECT. Please refer to Appendix C.5. S10: Enable Response Message
and turn off the corresponding option.

3.7. Pairing Button


Parani-SD1100 provides Pairing Button for instant configuration without a PC to make an automatic
connection between two Parani-SD1100s. In this example we will refer to the two Parani-SD1100s as
SD1 and SD2. (Only single connection mode)