Advanced topologies – GE Industrial Solutions WattStation Pedestal EVSE Charger Operation and Maintenance User Manual

Page 41

Advertising
background image

WattStation™ EV Charger User Manual

4411

GE Energy

©2012 GE Company All Rights Reserved


5.3.3

Advanced Topologies

Topology #7: Cellular + BMS

In this configuration connectivity is provided to the sites BMS system over the Ethernet
interface. The Cellular router is connected to the same LAN switch inside the unit and provides
Internet connectivity. A second unused switch port is connected to the Router or Gateway
device to the BMS network. In most cases a Static IP route must be configured in the
WattStation to reach the BMS network.























Figure – 4.24