GE Industrial Solutions WattStation Pedestal EVSE Charger Operation and Maintenance User Manual

Page 42

Advertising
background image

WattStation™ EV Charger User Manual

4422

GE Energy

©2012 GE Company All Rights Reserved


Topology #8: Ethernet + BMS

In this configuration connectivity is provided to the sites BMS system over the Ethernet
interface. Internet connectivity is provided by the site through a LAN connected gateway. The
BMS system resides on another network. The default route configured in the WattStation can
reach the Internet and the network the BMS resides on. No additional static IP routes are
required in this configuration.

















Figure – 4.25

Topology #9: WIFI + Ethernet + BMS

In this configuration connectivity is provided to the sites BMS system over the WIFI interface.
Internet connectivity is provided by the site through a LAN connected gateway. The BMS
system resides on a network reachable via WIFI.


















Figure – 4.26