4. The other wire harness supplied loose with kit shall be
connected to the RELT wire harness to signal the input or
output.
5. The wires in harness are color coded for input
and output. Yellow and red wires are for input to
trip unit.
Black and white wires are for output from trip
unit.
6. If required to use the power supply harness for
control power supply, rout the 2-wire harness in
same way above RELT wire harness.
Figure 18
Figure 19
Wire Colour
Slot in 36 pin
connector
Function
Red
4
Input +
Yellow
2
Input -
Black
30
Output +
White
27
Output -