3.5

MODBUS Operations

3.5.1

Read EVSE MODBUS Register Data Module Info


In this architecture design, the authorized master device can get the MODBUS Register Data Module
information which includes the ID, address offset, and length of the data module w/ Function Code 3.

3.5.2

Read EVSE MODBUS Register Data


The authorized master device can read any valid MODBUS registers using Function code 3 or 23 as
shown in section 3.3.

3.5.3

Control EVSE


In this architecture design, the authorized master device can issue MODBUS Control command to
control EVSE by writing an appropriate value to the corresponding command register using function
code 16 or 23.

The supported MODBUS Control commands are defined and mapped to MODBUS registers in section
4.2.

4

EVSE MODBUS Register Map

4.1

EVSE MODBUS Register Data Module Information Registers

EVSE Module Register Data Module

Information

Registers are designed to provide the information on

• Version of MODBUS Register Map.
• Number of MODBUS Data Register Modules in this version of MODBUS Register
Map.
• Data Module ID, Address Offset, and length of each module in the MODBUS
Register Map.

The

address offset for EVSE Module Register Data Module

Information

Registers

is defined as 00xx00000011 in this version of MODBUS Register Map.

MODBUS Data Model: Input registers (Read only)
The M

Moodduullee IID

D for EVSE Module Register Data Module

Information

Registers is defined as 00xx00.

Address

(hex)

MODBUS

Register

(decimal)

Variable

Name

Data

Range

Description

Properties

Offset

1

MODBUS

Register

Data Module

Information

Registers

Validity

0-1

Indicates whether the

values in the MODBUS

Data Module Information

Registers are valid or not.

0---Invalid

1---Valid

R

Offset+1

2

MODBUS

>=

Indicate the version of

R