18 GE Energy ©2012 GE Company All Rights Reserved

4.4

EVSE Current Charging Information Diagnostic Registers

EEVVSSEE C

Cuurrrreenntt C

Chhaarrggiinngg IInnffoorrm

maattiioonn RReeggiisstteerrss provide the user information about the current

charging being performed.

The aaddddrreessss ooffffsseett for EVSE current Charging Information registers is defined as 00xx00115555 ((334411 iinn
ddeecciim

maall nnoottaattiioonn)) in this version of MODBUS Register Map.


M

MO

OD

DBBU

USS D

Daattaa M

Mooddeell: Input registers (Read only)

The M

Moodduullee IID

D for EVSE last Charging Information registers is defined as 00xx33.

Address

(hex)

MODBUS

Register
(decimal)

Parameter

Data

Range

Description

Properties

Offset

341

Current
Charging
Information
Registers
Validity

0-1

This field indicates
whether the current
charging Registers
information are valid
or not.
0----Invalid
1----Valid

R

Offset+1

342

Current
Charging
Information
Registers
Version

0x1000 Indicate the version

of EVSE Current
Charging Information
Register
High byte ---- main
version.
Low byte ---- minor
version.
The current version
of EVSE Current
Charging Information
Register is 1.0.

R

Offset+2

343

Current
Charging
Status

0-1

This field indicates
whether EVSE
charging or not.
0----No Current
Charging
1----Current
Charging

R

Offset + 3 344

Temperature

-100-
100C

The temperature
inside the
WattStation

R

Offset + 4 345

Current

0-500A Current being

supplied to EV

Offset+5

346

Current
Charging
Maximum
Current

6-
current
rating

Maximum current
allowed to send to EV

R

Offset+6

347

Current

0-300V

R

Advertising