3! evse identification register – GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual

Page 17

Advertising
background image

WattStation

TM

EV Charger MODBUS Register Guide

17 GE Energy ©2012 GE Company All Rights Reserved

4.3

EVSE Identification Register


EVSE Identification Register is used to give the user a quick and big picture on what features the
current EVSE supports.


The address offset for EVSE Identification Register is defined as 00xx00114411 ((332211 ddeecciim

maall nnoottaattiioonn))

in this version of MODBUS Register Map.

MODBUS Data Model: Input registers (Read only)
The

Module ID for EVSE Identification Registers is defined as 00xx22

Address

(hex)

MODBUS

Register
(decimal)

Parameter

Data

Range

Description

Properties

Offset

321

EVSE
Identification
Register
Validity

0-1

Indicates whether
the values in the
EVSE Identification
Registers are valid
or not.
0---Invalid
1---Valid

R

Offset+1

322

EVSE
Identification
Register
Version

0x1000

Indicate the version
of EVSE
Identification
Register
High byte ---- main
version.
Low byte ---- minor
version.
The current version
of EVSE
Identification
Register is 1.0.

R

Offset+2+15 323+15

EVSE
Identification
Register—
Station ID

15 ASCII
characters

EVSE Station unique
identifier

R

EVSE Identification Registers

Table – 4.3

Advertising