4.2

EVSE MODBUS Operation Status Registers


EVSE Operation Status Register is used to give the user a quick and big picture
on the current EVSE operation status.


The

address offset for EVSE Operation Status Register is defined as 00xx001122D

D ((330011ddeecciim

maall

nnoottaattiioonn)) in this version of MODBUS Register Map
M

MO

OD

DBBU

USS D

Daattaa M

Mooddeell: Input registers (Read only)


The

Module ID for EVSE Operation Status Registers is defined as 00xx11.

MODBUS Operation Status Registers

Table – 4.2

Address

(hex)

MODBUS

Register

(decimal)

Variable

Name

Data

Range

Description

Properties

Offset

301

EVSE

Operation

Status

Register

Validity

0-1

Indicates whether the values
in the EVSE Operation Status
Registers are valid or not.
0---Invalid
1---Valid

R

Offset+1

302

EVSE

Operation

Status

Register

Version

0x1000 Indicate the version of EVSE

Operation Status Register
High byte ---- main version.
Low byte ---- minor version.
The current version of EVSE
Operation Status Register is
1.0.

R

Offset +

2

303

EVSE

Faulted

0-1

EVSE faulted state
0—Not Faulted
1—EVSE Faulted

R

Offset +

3

304

EV

Connected

0-1

EV Connected state
0—No EV connected
1—EV Connected

R

Offset +

4

305

EV

Charging

0-1

EV Charging state
0—EV not charging
1—EV Charging

R

Offset +

5

306

EVSE

Mode

0-2

EVSE Mode of operation
0-Unknown Mode
1-Online
2- Offline
3- Online Auth. Disabled
4-Reserved
5-Configuration mode
6- Update mode