4.5

EVSE MODBUS Diagnostic Registers


EVSE SNTP Diagnostics Registers allow the user to view the EVSE MODBUS Diagnostics

data.


The

address offset for EVSE MODBUS Diagnostics registers is defined as 00xx0011FF55 (501 in Decimal

notation) in this version of MODBUS Register Map.

MODBUS Data Model: Input registers (Read only)

The

Module ID for EVSE MODBUS Diagnostics registers is defined as 00xx44.

Address
(hex)

MODBUS
Register
(dec)

Parameter

Data
Range

Description

Properties

Offset

501

EVSE MODBUS
Diagnostic
Register Validity

Indicate if the
MODBUS
Diagnostics
register is valid or
not.
0----Invalid
1----Valid

R

Offset+1

502

EVSE MODBUS
Diagnostic
Register Version

0x1000 High byte ----

main version.
Low byte ----
minor version.
The current
version of EVSE
MODBUS
Diagnostics
Register is 1.0.

R

Offset+2

503

MODBUS Service
Feature Selected

0-2

0- Disabled
1- Basic function
2- Full function

R

Offset+3

504

MB Version
Application
Version

R

Offset+4

505

Maximum
Number MODBUS
Connections

R

Offset+5

506

Number of
MODBUS
Requests
Received
Bytes 3 and 2

R

Offset+6

507

Number of
MODBUS
Requests
Received
Bytes 1 and 0

0-
65535

R

Offset+7

508

Number of

0-

R