GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual

Page 21

Advertising
background image

WattStation

TM

EV Charger MODBUS Register Guide

21 GE Energy ©2012 GE Company All Rights Reserved

MODBUS
Responses Sent
Bytes 3 and 2

65535

Offset+8

509

Number of
MODBUS
Responses Sent
Bytes 1 and 0

0-
65535

R

Offset+9

510

Number of
MODBUS
Exceptions Sent
from the
Application

0-
65535

R

EVSE MODBUS Diagnostic Registers

Table – 4.5

4.6

EVSE MODBUS Connection Table Diagnostic Registers


EVSE MODBUS Connection Table Diagnostics Registers allow the user to view the EVSE MODBUS
Connection Table Diagnostics

data.


The

address offset for EVSE MODBUS Connection Table Diagnostics registers is defined as 00xx00225599

(601 in decimal notation) in this version of MODBUS Register Map.

MODBUS Data Model: Input registers (Read only)

The

Module ID for EVSE MODBUS Connection Table Diagnostics registers is defined as 00xx55..

Address
(hex)

MODBUS
Register

(dec)

Parameter

Data
Range

Description

Properties

Offset

601

MODBUS
Connection Table
Diagnostic
Register Validity

Indicate if the
MODBUS
Connection Table
Diagnostics
register is valid or
not.
0----Invalid
1----Valid

R

Offset+1

602

MODBUS
Connection Table
Diagnostic
Register Version

0x1000 High byte ----

main version.
Low byte ----
minor version.
The current
version of EVSE
MODBUS
Connection Table
Diagnostics
Register is 1.0.

R

Offset+2

603

Client Connection
1 Active

Indicate if
connection 1 is a