GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual
Page 21
WattStation
TM
EV Charger MODBUS Register Guide
21 GE Energy ©2012 GE Company All Rights Reserved
MODBUS
Responses Sent
Bytes 3 and 2
65535
Offset+8
509
Number of
MODBUS
Responses Sent
Bytes 1 and 0
0-
65535
R
Offset+9
510
Number of
MODBUS
Exceptions Sent
from the
Application
0-
65535
R
EVSE MODBUS Diagnostic Registers
Table – 4.5
4.6
EVSE MODBUS Connection Table Diagnostic Registers
EVSE MODBUS Connection Table Diagnostics Registers allow the user to view the EVSE MODBUS
Connection Table Diagnostics
data.
The
address offset for EVSE MODBUS Connection Table Diagnostics registers is defined as 00xx00225599
(601 in decimal notation) in this version of MODBUS Register Map.
MODBUS Data Model: Input registers (Read only)
The
Module ID for EVSE MODBUS Connection Table Diagnostics registers is defined as 00xx55..
Address
(hex)
MODBUS
Register
(dec)
Parameter
Data
Range
Description
Properties
Offset
601
MODBUS
Connection Table
Diagnostic
Register Validity
Indicate if the
MODBUS
Connection Table
Diagnostics
register is valid or
not.
0----Invalid
1----Valid
R
Offset+1
602
MODBUS
Connection Table
Diagnostic
Register Version
0x1000 High byte ----
main version.
Low byte ----
minor version.
The current
version of EVSE
MODBUS
Connection Table
Diagnostics
Register is 1.0.
R
Offset+2
603
Client Connection
1 Active
Indicate if
connection 1 is a
R