5.0 DRIVE PARAMETERS

The user parameters have an Offset referred to the type of drive linked to Interbus-S; in order to obtain the

parameter index, the specific Offset for that drive has to be added to the index of the drive parameter.

At present the Offsets are the following:

DRIVE

OFFSET (in

hexadecimal)

A V 3 0 0

2 0 0 0 h e x

D V 3 0 0

2 0 0 0 h e x

Example:

The DV300 drive parameter having the index

(which corresponds to 15 decimal) with InterBus-S has

the index 200Fhex.

The Drivecom parameters start with the index

6000h (hexadecimal); for their indexes see paragraph

5.2.1.1.4.2 of the manual

PROFILE 21.

The Drivecom parameters for the configuration of the process data channels

6001 h and 6002h are

implemented on all the cards in order to allow the configuration of the above-mentioned channels, which are
later described.

All the drive parameters can be transmitted through the PCP; as for the meaning of the parameters see the
drive manual.

,