7 process channel control – GE Industrial Solutions 6KCV300lNS User Manual

Page 14

Advertising
background image

GEI- 100445

6.7

Process

Channel Control

This function allows to assign drive parameters to the Process Data Channel Bytes.

In InterBus-S ring the

cards occupy a total of four words (WORD); the first Word (that is 16 Bit)

is represented by the PCP, while the following three are avaliable for the Process Data Channel
(abbreviation PDC).

Representation of the words occupied in InterBus-S ring by the

cards :

WORD 1

l l

WORD 2

n

.

WORD 3

l l

WORD 4

l

.

. . . . . . .

. . . . . .

.

l l

PDC 1

l

.

PDC 2

l l

PDC 3

l

. . . . . . . . ...*

. .

. . . ...*.....

The

card can both read and write the Process Data Channel.

The data read by the

card from InterBus-S are referred to as output data; the data written by

the

card in Interbus-S are referred to as input data.

l

Process Data

l

Drive parameters

.

.

. . . . . . . . . . . . . . . . . . . . .
.

.

.

.

l

*m Input data descriptor

.

P r o c e s s

.

.

C h a n n e l

.

l

** Output data descriptor

.

Control

.

.

.

l

-- Output data enable

l

.

. . . . . . ..*............

.

l

Process data

l

Drive parameters

.

Assigning the drive parameters to the communication object

Input data Descriptor,,, such parameters

are read with cyclicity by the Master.

Assigning the drive parameters to the communication object

Output data Descriptor),, the Master

transmits to the Server with cyclicity such parameters.