GE Industrial Solutions 6KCV300lNS User Manual

Page 32

Advertising
background image

GEI-100445

The InterBus-S parameter 5EFBh is a Record made up as follows:

ELEMENT

LENG.BYTE

MEANING

3

Parameter

4

V-PAR (Read

2

1

Result of the operation carried out

by the DGF (reading/writing etc.)

DGF Paramete type

2

DGF parameter index involved in

the operation

4

DGF parameter value read

(only by reading)

This is a read only parameter; the access to this parameter is possible in the following ways:

In case of writing DGF parameter: if this writing has a negative result the Result element (operation
result) contains the specific error cause (for the meaning of the error code see the DGF manuals).

In case of reading: if the reading has a positive result the V-PAR element contains the value of the
DGF parameter involved in the operation; if the reading has a negative result the Result element
(operation result) contains the specific cause of the error (for the meaning of the error code see the
DGF manuals).

for the elements with more than one Byte the order of the Bytes received starts always from the less

significant Byte to the most significant one.

The elements of this Record can be read one by one, by entering the subindex or all together (by setting the

subindex to 0) .

I

Description of parameter send a command to DGF option

OBJECT ATTRIBUTE

VALUE

Index

5EFAh

MEANING

Parameter send command to

DGF

Object code

09

Record

I

Index of the

of datum

21

Structure of DGF command

Password

00

Non-existing

Access group

00

Non-existing

Access rights

02

Write-All

Local address

x x x x

Specific

Range of the descriptor values:

Bubindex 1

: Unsigned8

Subindex 2

: Unsigned8

Subindex 3

: Unsigned1 6

Subindex 4

: Unsigned32

Advertising