S

Mounting

The

cards are provided with a kit made up of 4 spacers, 4 screws, washers and a 40-pole fiat

cable with connectors.

1. Switch the drive off.

2. The

card must be fixed with the screws and the spacers to the regulation card.

Hereby we are representing as an example the card R-TPD3.

Connectors linking the Bus are placed in the same direction of the terminals belonging to the regulation card.

3. The flat cable is connected to the connector

already existing on the cards.

4. The dip switch

determines the Slave

identification code; for

card

this code is

(Slave on local Bus PCP)

and it absolutely can not be changed
otherwise the Master will not be able to

identify the card correctly .

5. Link the input local Bus cable to the

connector XIN and eventually the output
cable to the connector XOUT.

6. Switch on the drive and supply the local

Bus.

7. The

and HO light up.

8. The LED H6 lights up when the Bus is

active.
The LED H3 lights up when a PCP service

is required.