11.2.1 Descriptors virtual digital output

The parameter 5EFDh is used to configure the virtual

output; it can be written/read through each

single element or as a whole object (by setting the subindex to 0).

OBJECT ATTRIBUTE

I

VALUE

I

MEANING

Index

5EFDh

Object code

08

virtual digital output configuration

Array

Number of the elements

16

16 Channels virtual digital output

06

Unsigned 16

Password

Access group

00

Non-existing

00

Non-existing

Access rights

Read-All,

Write-All

Local address

I

x x x x

I

Manufacterer Specific

The parameter 5EFFh is used to read the

virtual

digital output previously configured; the

status of the single Bits corresponds to the status of the

virtual

digital output assigned to the

Bit during the configuration:

OBJECTATTRIBUTE

Index

VALUE

5EFFh

MEANING

Value (current status)

virtual digital output

Object code

07

I

Single variable

Index of the type of datum

05

The status of the single Bit

corresponds to the

status

of the

virtual digital output assigned

Length

Password

Access group

Access rights

Local address

02

2 Byte

00

Non-existing

00

Non-existing

I

01

1

Read-All

x x x x

Manufacterer Specific

Advertising