12.2

Description of reading value of DGF parameter

OBJECT ATTRIBUTE

VALUE

Index

5 E F B h

Object code

09

Index of the type of datum

22

Password

00

Access group

00

MEANING

Parameter reading value DGF

parameter

Record

Structure reading DGF

parameter

Non-existing

Non-existing

Access rights

I

01

I

Read-All

II

Local address

x x x x

Specific

Range of the descriptor values:

Subindex 1

: Unsigned1 6

Subindex 2

: Unsigned8

Subindex 3

: Unsigned1 6

Subindex 4

: Unsigned32

12.3

Example for access DGF parameters

12.3.1 Writing DGF parameter

2 -

3 -

Fill the elements of the InterBus-S parameter 5EFAh in the following way:

Element Command

a command writing DGF parameter.

Element Type with DGF parameter type.
Element

with DGF parameter index.

Element V-PAR with DGF parameter value (4 Bytes have always to be written; in the case of
DGF parameters with a length less then 4 Bytes fill the remaining Bytes with 0).

The elements with more than one Byte must always be filled starting from the less significant Byte to
the most significant one.

Carry out the InterBus-S ‘Write’ service by always setting the Interbus-S subindex to 0 and wait for
the response.

If the response is positive, the value of the DGF parameter has been correctly written.

If the response is negative, the error cause can be found by reading, with the Interbus-S “Read”

service , the Result element (operation result) of the Interbus-S parameter 5EFBh. The single element
can be read by setting the subindex to 1, or the whole parameter can be read by setting the subindex
to 0 (in this case the V-PAR element has no meaning).