Rear panel features and connections, Power connections, Figure 6. ipcp 505 rear panel – Extron Electronics IPCP 505 User Guide User Manual

Page 17: Figure 7. switched power output ports

Advertising
background image

IPCP 505 • Hardware Features and Installation

11

Rear Panel Features and Connections

FLEX I/O

LAN

1 2 3 4 G

COM1

TX RX G

G

G

G

IR/SERIAL

RELAY

5

S G S G

6

1

S G S G

2

3

S G S G

4

7

S G S G

8

5

6

1

2

3

4

7

8

COM2

TX RX

TX RX G

G

TX RX

COM3

TX RX

G

TX RX

COM7

COM4

CTS

COM5

COM6

COM8

TX RX

5A MAX

100-240V 50-60Hz

MAC:

00-05-A6-XX-XX-XX

S/N:

RTS

G

CTS

TX RX

RTS

SWITCHED 12VDC

40W MAX TOTAL

+ - + -

+ - + -

1

2

3

4

Rear Panel

1

2

3

7

8

9

6

5

Flex I/O

(digital input/

output or

analog input)

ports

Relay

ports

IR/serial

output

ports

COM7, COM8

RS-232/

RS-422/

RS-485 ports

MAC

address

COM1 -

COM6

RS-232 ports

Switched

12 VDC power

output ports

LAN

(Ethernet)

connector

and LEDs

Power input

connector

4

Figure 6.

IPCP 505 Rear Panel

Power Connections

a

Power input connector — Connect the IPCP to a 100-240 VAC power source here.

b

Switched 12 VDC power output ports — These four ports provide 12 VDC output

up to a combined maximum of 40 watts. Once configured, each port can be separately
turned on or off. These ports are monitored continuously for total power usage (draw).

R

SWITCHED

12VDC

3

1

4

OVER

2 LIMIT

IPCP 505

5A MAX

100-240V 50-60Hz

SWITCHED 12VDC

40W MAX TOTAL

+ - + -

+ - + -

1

2

3

4

Lights if total power draw is

40-44 watts.

Lights if total power draw

exceeds

44 watts.

Power output shuts off.

The user must turn these

ports back on.

Switched 12 VDC

Power Output

• 12 VDC, 40 watts (max.)

= total output for all four ports

combined

• Corresponding front panel

green LEDs ( ) light when

power is available at each port.

Tie Wrap

3/16"

(5 mm)

Max.

Power Input

• Front panel LED lights when

the IPCP receives power.

• Connect to 100 to

240 VAC.

Rear Panel

Front Panel

Figure 7.

Switched Power Output Ports

When the total power usage exceeds a threshold of 40 watts but is still below
44 watts, the IPCP enters the

limit mode, during which the yellow front panel

Limit LED lights. If you have configured the unit to do so, the IPCP can issue a power
overcurrent notice.

If power usage exceeds a second, higher threshold (44 watts), the IPCP enters
overcurrent mode. It turns these ports off, and the red front panel Over LED lights.
If the ports are disabled, the user must disconnect or fix the attached devices to
correct the problem, after which power output can be re-enabled via controls in the
IPCP internal web pages or via an SIS command.

(page

11

)

(page

15

)

(page

15

)

(page

11

)

(page

12

)

(page

14

)

(page

12

)

(page

13

)

(page

13

)

Advertising