Extron Electronics MVC 121 Plus User Guide User Manual

Page 16

Advertising
background image

g

Volume level adjust knob — Rotating the adjustment knob clockwise increases the

output volume, rotating the knob counterclockwise decreases the volume. The LEDs
light from bottom up as the volume level increases.

VOLUME

MIXER/VOLUME CONTROLLER

MVC 121 Plus

Use the rotary encoder to adjust the output volume from 0 (-100 dB) to 100% (0 dB).
The default setting is 100% (0 dB). The knob step adjustments are as follows:

Volume

Range (dB)

Knob Step

Adjustment

(dB)

-100 to -70

+/- 5 dB

-70 to -30

+/- 3 dB

-30 to -20

+/- 2 dB

-20 to -0

+/- 1 dB

The degree to which the volume is incremented or decremented for each step the
volume adjust knob is turned, depends on the current volume setting.
As the volume increases or decreases, the LED bar lights to indicate the current
volume range, as shown in the table below. As the volume is increased or decreased
within a volume range, the top LED to be lit flashes once. If the knob is turned past
maximum volume, all 8 LEDs flash, for as long as the knob continues to be turned.
In the table below, turning the volume adjust knob (g) affects the volume range and
turning the input gain control screws (c, d, e affects the mix-point range).

LED

Level

Volume Range

(dB)

Mix-point
Range (dB)

8

-4 to -0

+7 to +12

7

-9 to -5

+1 to +6

6

-14 to -10

-3 to +0

5

-19 to -15

-7 to -4

4

-29 to -20

-11 to -8

3

-49 to -30

-15 to -12

2

-69 to -50

-19 to -16

1

-99 to -70

-23 to -20

MVC 121 Plus • Installation