Digital Input Commands

Command

ASCII Command

(Host to Tuner)

Response

(Tuner to Host)

Additional Description

Configure digital input

E X! * X@ GPIT }

Gpit X! * X@ ]

Tagged response

View digital input

E X! GPIT }

(Vrb mode 2/3:)

X@* ]
Gpit X! * X@ ]

Tagged response

View I/O state

X! ]

Vrb mode 2/3:

X% ]
Sio X! * X% ]

Tagged response

X!

= Digital inputs, 1–3

Inputs 1–3

X@

= Type of change to monitor

0

= Off (default)

1

= Edge, Hi to Lo

2

= Edge, Lo to Hi

3

= Logic level Lo

4

= Logic level Hi

X%

= State

0

= Logic Hi (inactive)

1

= Logic Lo (active)