Error responses, Command/response table for basic sis commands, Symbol definitions – Extron Electronics MVC 121 Plus User Guide User Manual

Page 37: Command/response table for basic sis, Commands

Advertising
background image

Error Responses

When the MVC 121 Plus is unable to execute the command, it returns an error response
to the host. The error response codes and their descriptions are as follows:

Code

Description

E01

Invalid input number

E10

Invalid command

E13

Invalid value (out of range)

E14

Not valid for this configuration

E23

Firmware update failure

Although the MVC uses the same structure for SIS commands, there are two variations.
One is the global command structure documented in the

Command/Response Table for

Basic SIS Commands

that follows.

The second set of tables for DSP SIS commands uses the command structure outline
beginning with

Command/Response Tables for DSP SIS Commands

on page 36. While

using the same structure of basic SIS commands, they differ in how the software addresses
the individual processor blocks within the MVC 121 Plus.
Generally the basic SIS commands are used for global configuration such as setting a unit
name, while the Audio SIS commands provide gain, volume, and mute control in the audio
signal chain.

Command/Response Table for Basic SIS Commands

Symbol definitions

]

=

CR/LF (carriage return/line feed) (hex 0D 0A)

}

=

Carriage return (no line feed, hex 0D)

=

Space character

|

=

Pipe (vertical bar) character

E

=

Escape key (hex 1B)

=

=

Future capability (not currently available)

X!

= Mix-point Input selection

1

= Mic 1 Mix-point

2

= Mic 2 Mix-point

3

= Line 3 Mix-point

X@

= Output Volume (variable)

0

(mute) to

100

(max volume) in 1% steps

X#

= On/Off

0

= off/mute

1

= on/unmute

X$

= Mix-point gain values increment/

decrement

-24

to

+12

dB in 1 dB steps

X^

= Dirty status

0

= RAM has been saved to Flash (OK to power off/reset)

1

= RAM needs to be saved to Flash

X&

= Output Volume Adjustment Range

0

(no output) to

100

(full output) in 1% steps

X*

= Soft Limit (Hi)

Value must be higher than low soft limit or device responds with E13 error.

X(

= Soft Limit (Low)

Value must be lower than high soft limit or device responds with E13 error.

X1)

= Executive Mode

0

= Disabled / Full control

1

= Enabled / no front panel control

2

= Enabled / volume control only

MVC 121 Plus • SIS Programming and Control

31