Command/Response Table for Basic MVC 121 Plus SIS commands

Command

ASCII Command

(Host to Tuner)

Response

(Tuner to Host)

Additional Description

NOTE:

Commands can be entered back-to-back in a string, with no spaces. Example: TvprS25*11•3

Upper and lower case may be used interchangeably.

General commands

Firmware Version, Part Number, and Model Information
Query firmware version

Q

X1# ]

Show the current firmware
version.

Query firmware and build
version

*Q

X1$ ]

Show the current firmware
and build version.

Query part number

N

60-1096-01

]

Show the unit part number.

Query model name

1I

MVC

121

Plus

]

Show the model name.

Query model description

2I

Mixer

Volume

Controller

]

Setup Commands

Set verbose mode

E X2$

CV

}

Vrb

X2$ ]

Set verbose/response mode.

View verbose mode

E

CV

}

X#

]

View verbose mode

Bi-directional Serial Data Port

NOTE:

CP and CV commands apply to both RS-232 and USB ports.

Configure parameters

E X3$

CP

}

Ccp

X3$

]

Set baud rate:

0 = 9600
1 = 19200
2 = 38400 (default)
3 = 115200

View parameters

E

CP

}

Ccp

X3$

]

View baud rate.

ZAP Commands (Factory Defaults) and RAM Commands
System reset (factory default)

E

ZXXX

}

Zpx

]

Reset system to factory default
except for the baud rate.

Absolute system reset

E

ZQQQ

}

Zpq

]

Similar to system reset, plus
sets the baud rate to factory
default.

View internal temperature
status in degrees Celsius

20S

Sts20*

X2@ ]

View internal temperature in
degrees Celsius.

Commit only RAM to Flash

E

2FF

}

Nvr

X^

]

(responds when done)

0 = RAM has been saved to Flash

(OK to power off/reset)
1 = RAM needs to be saved to Flash

Query whether RAM needs to
be saved to Flash

E

FF

}

X^

]

Name Commands
Write input name

E

X1!

, name

NI

}

Nmi

X1!

, name

]

name = maximum 12
characters.
Invalid characters: = ~ , @ ’
[ ] { } < >” ” ; : | \ ?

Read input name

E

X1!

NI

}

Vrb mode 0/1:

name

]

Vrb mode 2/3:
Nmi

X1!

, name

]

Read input name.

Write output name

E

X1@

, name

NO

}

Nmo

X1@

, name

]

name = maximum 12
characters.
Invalid characters: = ~ , @ ‘
[ ] { } < >“ ” ; : | \ ?