Extron Electronics MVC 121 Plus User Guide User Manual

Page 23

Advertising
background image

Fader Handle

Signal Level

Clicking the fader handle or clicking within the fader area brings focus to the fader.
The input signal level can be adjusted using any of the following methods:

Direct adjustment. Click and hold the fader handle, then drag it to the desired
level in 0.1 dB steps.

Click or tab to the fader handle, then <up arrow> or <down arrow> to the
desired level in 1 dB steps. Page Up and Page Down increases or decreases level in
10 dB steps.

Click in or tab to the signal level readout field. Type a new value, then press
<Enter> or <Tab> to another area.

Filter (FILT) – Up to five filters per input can be inserted in any combination of High
Pass, Low Pass, Bass & Treble shelving (tone), or Parametric Equalizer.

Line input 3

Gain (GAIN) — Stereo (left/right) gain control with a range from -18 to +24 dB
includes mute buttons. Step resolution is 0.1 dB. Left and right polarity switches
(+ or -) are provided. Gain control is provided pre-meter and mute control is provided
pre-meter. A Gang switch ties the two input levels together.

Filter (FILT) — Up to three filters can be inserted in any combination of High Pass,
Low Pass, Bass & Treble shelving (tone), or Parametric Equalizer.

MVC 121 Plus • Operation

17