Selected SIS

Commands

You can use Simple Instruction Set (SIS) commands for

operation and configuration of the switchers. You can run these

commands from a PC connected to a serial port (

i

,

j

, and

m

on pages 2-5 and 2-6), Ethernet port (

k

), or USB port (

n

) on the

switcher.

Establishing a network (Ethernet) connection

N

If you connect to the switcher via the LAN port, and it

is the first time you have done so, you may change the

default settings (IP address, subnet mask, and [optional]

administrator name and password) of the controller. See

"

Configuring for Network Communication

" on page 4-24

for details.

Establish a network connection as follows:
1

.

Open a TCP socket to port 23 using the IP address of the

switcher.

N

The factory default IP address is 192.168.254.254.

The switcher responds with a copyright message including

the date, the name of the product, firmware version, part

number, and the current date and time.

N

If the switcher is not password-protected, the device is now

ready to accept SIS commands.

N

If the switcher is password-protected, a

password

prompt appears.

2

.

If the switcher is password-protected, enter the appropriate

password.

If the password is accepted, the switcher responds with

Login User or Login Administrator.

If the password is not accepted, the

Password prompt

reappears.

Connection timeouts

The Ethernet link times out and disconnects after a designated

period of time of no communications. By default, this timeout

value is set to 5 minutes but the value can be changed. See the

Configure port timeout

SIS command on page 4-14.

N

Extron recommends leaving the default timeout at

5 minutes and periodically issuing the Query (Q)

command to keep the connection active or disconnecting

the socket and reopening the connection when necessary.

Number of connections

A switcher can have up to 200 simultaneous TCP connections,

including all HTTP sockets and Telnet connections. When

the connection limit is reached, the switcher accepts no new

connections until some have been closed. No error message or

indication is given that the connection limit has been reached.

To maximize performance of your switcher, keep the number of

connections low and close unnecessary open sockets.

Verbose mode

Telnet connections to a switcher can be used to monitor

for changes that occur on the switcher, such as front panel

operations and SIS commands from other Telnet sockets or a

serial port. For a Telnet session to receive change notices from

the switcher, the Telnet session must be in verbose mode 1 or 3.

See the

Set verbose mode

SIS command on page 4-14. In

verbose mode 3, the Telnet socket reports changes using

messages that resemble SIS command responses.

Establishing a USB port connection

A standard USB cable and the Extron DataViewer utility, version

2.0 or newer, can be used for connection to the MTPX Plus 128

Configuration port. The USB cable, available at any local

electronics store, should be terminated on one end with a mini

USB B male connector

N

Before you use the USB port for the first time, install

the USB driver on your computer. The simplest way to
do this is to install

version 7.7 or newer of the Matrix

Switchers Control Program and then run the Found
New Hardware Wizard. See

Installing the program

,“

on page 4-5 and

First-time connection considerations

on page 4-16.

Host-to-switcher instructions

The switcher accepts SIS commands through either serial port,

the USB port, or the LAN port. SIS commands consist of one

or more characters per command field. They do not require

any special characters to begin or end the command character

sequence. Each switcher response to an SIS command ends with

a carriage return and a line feed (CR/LF =

]

), which signals

the end of the response character string. A string is one or more

characters.

N

The table that begins on the next page is a partial list

of SIS commands. For a complete listing, refer to the

MTPX Plus User's Manual.