Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Output skew adjustment

Set all output skew adjustment
values

EX@

*

X*

*

X*

*

X*

Oseq

}

Oseq

X@

*

X*

*

X*

*

X*]

Set a specific skew adjustment for the TP
output.

X*

values are listed in RGB order.

Example:

E

2*0*0*4Oseq

}

Oseq02*0*0*4

]

Set output 2’s skew settings as follows:
Red = 0 ns
Green = 0 ns
Blue = 8 ns (delayed 8 ns).

Increment one output skew
adjustment value

EX@

*

X(

+Oseq

}

Oseq

X@

*

X*

*

X*

*

X*]

Increase the

X(

skew plane adjustment for

output

X@

by 1 step (2 ns).

Decrement one output skew
adjustment value

EX@

*

X(

-Oseq

}

Oseq

X@

*

X*

*

X*

*

X*]

Decrease the

X(

skew plane adjustment for

output

X@

by 1 step (2 ns).

Example:

E

2*2*-Oseq

}

Oseq02*0*0*3

]

Decrease the blue skew for output 2 by
2 ns (from 8 ns to 6 ns).

Read output skew adjustment
values

EX@

Oseq

}

X*

*

X*

*

X*]

Output pre-peaking

Set output pre-peaking on

EX1)

*1Opek

}

Opek

X1)

*1

]

Pre-peak the TP output.

Set output pre-peaking off

EX1)

*0Opek

}

Opek

X1)

*0

]

Do not pre-peak the TP output.

Read output pre-peaking setting

EX1)

Opek

}

X1!]

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Local video output sync polarity

N

The command structure differs, depending on the size of the matrix. Matrix sizes 1616 and smaller, excluding the MTPX Plus 128, do not

need the local output variable (

X1#

). The MTPX Plus 128 and matrix sizes 1632 and larger require the variable.

Set local output polarity
(matrix size 1616 and smaller)

EX1@

Opol

}

Opol

X1@]

Set the horizontal and vertical sync
polarity for a local output.

Example:

E

0Opol

}

Opol0

]

Set the local output to output negative
horizontal and vertical sync.

Set local output polarity
(matrix size 1632 and larger)

EX1#

*

X1@

Opol

}

Opol

X1#

*

X1@]

Set the horizontal and vertical sync
polarity for local output

X1#

.

Example:

E

2*0Opol

}

Opol2*00

]

Set local output 2 to output negative
horizontal and vertical sync.

Read local output sync settings
(matrix size 1616 and smaller)

E

Opol

}

X1@]

Read local output sync settings
(matrix size 1632 and larger)

EX1#

Opol

}

X1@]

N

X1@

= Local output sync polarity

0 = H- / V- (default)

1 = H+ / V-

2 = H- / V+

3 = H+ / V+

4 = NTSC (no sync stripping)

X1#

= Local video output number

1 (matrix sizes 1616 and smaller)

1 or 2 (matrix sizes 1632 and larger)

N

X@

= Output number

01 – (maximum number of inputs for your model)

X*

= Skew adjustment range

00 – 31 (each step = 2 ns)

X(

= Video plane

0 = red, 1 = green, 2 = blue

X1)

= Pre-peakable output number 01 – half of the outputs for your matrix switcher model (such as 04 for MTPX Plus 168)

X1!

= Pre-peaking

0 = off

1 = on

MTPX P

lus Series • Remote Contr

o

l and Optimizing the V

ideo

Remote

Contr

ol
and

Optimizing

the

V

ideo,

cont’d

4-8

MTPX P

lus Series • Remote Contr

o

l and Optimizing the V

ideo

4-9