Manually setting the MTPX level and peaking

If you choose not to auto calibrate, or if you want to fine tune

the adjustment, you can manually set the values as follows:
1

.

Connect an oscilloscope (preferred) or a monitor

(acceptable) to local output (VGA output) 1.

2

.

If using an oscilloscope

, apply a white field test pattern to

the input to be optimized via an MTP transmitter.

If using a monitor

, apply a grayscale or Color Bars

test pattern to the input to be optimized via an MTP

transmitter.

H

The Extron VTG 300 or VTG 400 are recommended to

provide the test pattern.

3

.

Tie the input to be optimized to output 1.

4

.

Click Tools > MTPX Picture settings.

5

.

Observe the oscilloscope or the monitor with a critical

eye while you adjust the input level/peaking setting to

compensate for signal loss between the transmitter and the

MTPX.

6

.

If necessary, repeat steps 1 through 5 for each input.

Setting MTPX skew

1

.

Connect an oscilloscope (preferred) or a monitor

(acceptable) to local output (VGA output) 1.

2

.

Apply a crosshatch test pattern to the input to be

optimized via an MTP transmitter.

3

.

Tie the input to be optimized to output 1.

4

.

Use the test equipment or examine the displayed video

image with a critical eye to determine which video

signal — red, green, or blue — is most shifted to the left.

5

.

If necessary, click Tools > MTPX Picture settings.

6

.

Adjust the skew setting of the leftmost video signal to the

right until all three colors are properly converged.

N

When the skew adjustment is set to zero, the MTPX Plus

cannot shift the rightmost video image to the left.

N

A 2-nanosecond adjustment is very fine. Up to 10

nanoseconds of delay may be necessary before you detect a

change in the display.

6

.

Adjust the skew setting of the leftmost video signal to the

right until all three colors are properly converged.

7

.

If either of the two remaining colors is left shifted, repeat

steps 4 and 6.

8

.

Repeat steps 2 through 7 for all other inputs.

9

.

Connect an oscilloscope (preferred) or a monitor

(acceptable) to the MTPX twisted pair output to be

adjusted, via an MTP receiver.

10

. Apply a crosshatch test pattern to one of the local (VGA)

inputs on the MTPX Plus.

11

. Tie the local input receiving the test pattern signal to the

output to be optimized.

12

. Use the test equipment or examine the displayed video

image with a critical eye to determine which video

signal — red, green, or blue — is most shifted to the left.

13

. If necessary, click Tools > MTPX Picture settings.

N

When the skew adjustment is set to zero, the MTPX Plus

cannot shift the rightmost video image to the left.