MTPX Twisted Pair Matrix Switchers • Installation

2-2

Installation

PRELIMINAR

Y

Mounting the Switcher

UL guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the installation

of the MTPX into a rack.

1

.

Elevated operating ambient temperature —

If the equipment installed in a

closed or multi-unit rack assembly, the operating ambient temperature of the

rack environment may be greater than room ambient temperature. Therefore,

install the MTPX in an environment compatible with the maximum ambient

temperature (Tma = +122 °F, +50 °C) specified by Extron.

2

.

Reduced air flow —

Install the equipment in a rack so that the amount of air

flow required for safe operation of the equipment is not compromised.

3

.

Mechanical loading —

Mount the equipment in the rack so that a hazardous

condition is not achieved due to uneven mechanical loading.

4

.

Circuit overloading —

Connect the equipment to the supply circuit and

consider the effect that circuit overloading might have on overcurrent

protection and supply wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing this concern.

5

.

Reliable earthing (grounding) —

Maintain reliable grounding of

rack-mounted equipment. Pay particular attention to supply connections

other than direct connections to the branch circuit (e.g. use of power strips).

Mounting instructions

The MTPX Twisted Pair matrix switchers are housed in a rack-mountable,

2U (matrix sizes 1616 and smaller) or 3U (matrix sizes 1632 and larger) high metal

enclosures with mounting flanges for standard 19" racks. If desired, rack mount the

switcher as follows:

1

.

Insert the switcher into the rack, aligning the holes in the mounting bracket

with those in the rack (figure 2-1).

2

.

Secure the switcher to the rack using the supplied bolts.

N

Extron recommends that you allow 1U of rack space above and below the

switcher for ventilation.

Figure 2-1 — Installing the switcher in a rack