Command/response table for sis commands, Symbol definitions, Symbol definitions -5 – Extron Electronics MTPX Series User Guide User Manual

Page 85: Preliminar y

Advertising
background image

4-5

MTPX Twisted Pair Matrix Switchers • Programmer’s Guide

PRELIMINAR

Y

Command/Response Table for SIS Commands

Symbol definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D))

= Space character

E

= Escape key (hex 1B)

X!

= Input number (for tie)

00 – (maximum number of inputs for your model) (00 = untied)

X@

= Output number

01 – (maximum number of outputs for your model)

X#

= Input number

01 – (maximum number of inputs for your model)

X$

= Audio/RS-232 input type

0 = audio

1 = RS-232

X%

= Pre-peakable output number

MTPX 168

01 – 02

MTPX 816, MTPX 1616, MTPX 3216

01 – 04

MTPX 1632, MTPX 3232

01 – 08

X^

= Mute, pre-peaking, Lock mode, power supply

0 = off/mode 0/not OK

1 = on/mode 1/OK

2 = mode 2

X&

= Local video output number

1 or 2 (matrix sizes 1632 and larger)

N

X&

is applicable to matrix sizes 1632 and larger only.

X*

= Local output sync polarity

0 = H- / V- (default)

1 = H+ / V-

2 = H- / V+

3 = H+ / V+

4 = No sync processing (composite, S-video, YUV)

X(

= Local audio output number

1 – 4 (matrix sizes 1616 and smaller)

1 – 8 (matrix sizes 1632 and larger)

X1)

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)

(default = 64 [0dB])

(See the table on page 4-8.)

X1!

= Audio gain

0 – 24 (1 dB/step)

X1@

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X1#

= Audio attenuation

1 – 18 (1 dB/step)

X1$

= Global preset #

0 - 32 (0 = current configuration)

X1%

= Name

12 characters maximum for input, output, and global preset names

Upper- and lower-case alphanumeric characters and

_ / and spaces are valid.

N

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1^

= Mute:

0 = not muted

2 = audio mute

X1&

= Local input select DIP switch status

0 = RJ-45 position, 1 = local input position

X1*

= Input level/peaking status

0 = not within threshold, 1 = within threshold

X1(

= Baud rate

9600, 19200, 38400, 115200

X2)

= Parity

O

dd, even, none, mark, space (Only the first letter is required.)

X2!

= Data bits

7, 8

X2@

= Stop bits

1, 2

X2#

= Port type

0 = RS-232, 1 = RS-422

X2$

= Number of inputs

8, 16, or 32

X2%

= Number of outputs

8, 16, or 32

X2^

= Part number

68-nnn-nn

X2&

= Firmware version number to second decimal place (x.xx)

X2*

= Verbose firmware version-description-upload date/time See the Query firmware version (verbose) command on page 4-14.

X2(

= Voltage

Positive or negative voltage and magnitude

X3)

= Internal temperature

Degrees Fahrenheit

X3!

= Fan speed

RPM

Advertising