Brickcom OSD-200 20xp User Manual

Page 52

Advertising
background image

48

b. Detection level [1-100]:

The default level is 10. The item is to set detection level for each

sampling pixel; the smaller the value, the more sensitive it is.

c. Sensitivity level [1-100]:

The default level is 80, which means if 20% or more sampling pixels

are detected differently, system will detect motion. The bigger the

value, the more sensitive it is. Meanwhile, when the value is bigger,

the red horizontal line in the motion indication window will be lower

accordingly.

d. Time interval (sec) [0-7200]:

The default interval is 10. The value is the interval between each

detected motion.

C. Triggered Action (Multi-option)

The Administrator can specify alarm actions that will take when motion

is detected. All options are listed as follows:

a. Enable Alarm Output 1/2

Check the item and select the predefined type of alarm output to

enable alarm relay output when motion is detected.

b. Send Alarm Message by FTP/E-Mail

The Administrator can select whether to send an alarm message by

FTP and/or E-Mail when motion is detected.

c. Upload Image by FTP

Select this item and the Administrator can assign a FTP site and

configure various parameters. When motion is detected, event

images will be uploaded to the appointed FTP site.