"^" Button Commands (Cont.)

^GLL

Change the

bargraph lower
limit

Change the bargraph lower limit.

Syntax:

"'^GLL-<vt addr range>,<bargraph low>'"

Variable:

• variable text address range = 1 - 4000.

• bargraph limit range = 1 - 65535 (bargraph lower limit range).

Example:

SEND_COMMAND Device,"'^GLL-500,150'"

Changes the bargraph lower limit to 150.

^GRD

Change the

bargraph

ramp-down time
in 1/10th of a

second

Change the bargraph ramp-down time in 1/10th of a second.

Syntax:

"'^GRD-<vt addr range>,<bargraph ramp down time>'"

Variable:

• variable text address range = 1 - 4000.

• bargraph ramp down time = In 1/10th of a second intervals.

Example:

SEND_COMMAND Device,"'^GRD-500,200'"

Changes the bargraph ramp down time to 20 seconds.

^GRU

Change the

bargraph

ramp-up time in

1/10th of a

second

Change the bargraph ramp-up time in 1/10th of a second.

Syntax:

"'^GRU-<vt addr range>,<bargraph ramp up time>'"

Variable:

• variable text address range = 1 - 4000.

• bargraph ramp up time = In 1/10th of a second intervals.

Example:

SEND_COMMAND Device,"'^GRU-500,100'"

Changes the bargraph ramp up time to 10 seconds.

^GSC

Change the

bargraph slider
color or joystick
cursor color

Change the bargraph slider color or joystick cursor color. A user can also assign the color
by Name and R,G,B value (RRGGBB or RRGGBBAA).

Syntax:

"'^GSC-<vt addr range>,<color value>'"

Variable:

• variable text address range = 1 - 4000.

• color value = Refer to theRGB Values for all 88 Basic Colors table on page 35.

Example:

SEND_COMMAND Device,"'^GSC-500,12'"

Changes the bargraph or joystick slider color to Yellow.