AMX Mio Modero R-4 User Manual

Page 69

Advertising
background image

Programming the Mio R-4

61

Mio Modero R-4

"^" Button Commands (Cont.)

^GSN

Change the

bargraph slider
name or joystick
cursor name

Change the bargraph slider name or joystick cursor name. Slider names and cursor
names can be found in the TPDesign4 slider name and cursor drop-down list.

Syntax:

"'^GSN-<vt addr range>,<bargraph slider name>'"

Variable:

• variable text address range = 1 - 4000.

• bargraph slider name = See table below.

Example:

SEND_COMMAND Device,"'^GSN-500,Ball'"

Changes the bargraph slider name or the Joystick cursor name to ’Ball’.

^ICO

Set the icon to a
button

Set the icon to a button.

Syntax:

"'^ICO-<vt addr range>,<button states range>,<icon index>'"

Variable:

• variable text address range = 1 - 4000.

• button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

1 = Off state and 2 = On state).

• icon index range = 0 - 9900 (a value of 0 is clear).

Example:

SEND_COMMAND Device,"'^ICO-500.504&510.515,1&2,1'"

Sets the icon for On and Off states for buttons with variable text ranges of 500-504 &

510-515.

Bargraph Slider Names:

Circle -M

None

Circle -S

Ball

Precision

Circle -L

Rectangle -L

Rectangle -M

Rectangle -S

Windows

Windows Active

Joystick Cursor Names:

Circle

None

Crosshairs

Arrow

Gunsight

Ball

Hand

Metal

Spiral

Target

View Finder