ALLIED Vision Technologies Goldeye P-032 SWIR User Manual

Page 45

Advertising
background image

Data interface

Goldeye Technical Manual V2.5.0

45

The camera can be single triggered or periodically triggered with a fixed frame
rate (t

p

) up to the maximum frame rate of 118 fps (Goldeye xy-008) or 30 fps

(Goldeye xy-032).

Figure 15: Trigger input diagram (TriggerSelector = ExposureActive)

Figure 16: Trigger input diagram (TriggerSelector = ExposureStart)

Goldeye xy-008

Goldeye xy-032

t

P

: Trigger period

t

P

: Trigger period

t

EXP

: Exposure time

t

EXP

: Exposure time

t

TRG

: Exposure start pulse (

μs)

t

TRG

: Exposure start pulse (

μs)

t

R

: Readout time

t

R

: Readout time

t

R

= 8.2 ms (320 x 256)

t

R

= 32.4 ms

t

R

= 5.1 ms (320 x 160)

t

F

: Frame period (t

F

= t

P

)

t

F

: Frame period (t

F

= t

P

)

t

Fc

: Frame period in continuous mode

t

Fc

: Frame period in continuous mode

t

Fc

= 8.45 ms (320 x 256)

t

Fc

= 33.0 ms

Table 20: Trigger input values

Advertising
This manual is related to the following products: