ST100 Series Foundation Fieldbus

Fluid Components International LLC

9

INDEX

PARAMETER

DATA TYPE (LENGTH)

INITIAL VALUE

DESCRIPTION

34

WRITE_LOCK

Unsigned8

1

35

UPDATE_EVT

DS-73

36

BLOCK_ALM

DS-72

37

ALARM_SUM

DS-74

38

ACK_OPTION

Bit String

0

39

WRITE_PRI

Unsigned8

0

40

WRITE_ALM

DS-72

41

ITK_VER

Unsigned16

42

FD_VER

Unsigned16

1

43

FD_FAIL_ACTIVE

Bit String

0

44

FD_OFFSPEC_ACTIVE

Bit String

0

45

FD_MAINT_ACTIVE

Bit String

0

46

FD_CHECK_ACTIVE

Bit String

0

47

FD_FAIL_MAP

Bit String

48

FD_OFFSPEC_MAP

Bit String

49

FD_MAINT_MAP

Bit String

50

FD_CHECK_MAP

Bit String

51

FD_FAIL_MASK

Bit String

52

FD_OFFSPEC_MASK

Bit String

53

FD_MAINT_MASK

Bit String

54

FD_CHECK_MASK

Bit String

55

FD_FAIL_ALM

DS-87

0;0;0,0;0;0;0;15;0;0

56

FD_OFFSPEC_ALM

DS-87

0;0;0,0;0;0;0;16;0;0

57

FD_MAINT_ALM

DS-87

0;0;0,0;0;0;0;17;0;0

59

FD_FAIL_PRI

Unsigned8

0

60

FD_OFFSPEC_PRI

Unsigned8

0

61

FD_MAINT_PRI

Unsigned8

0

62

FD_CHECK_PRI

Unsigned8

0

63

FD_SIMULATE

SIMULATE_FD

0;0;1

64

FD_RECOMMEN_ACT

Unsigned16

0

Process Data Transducer Block
This block connects the ST100 sensor process Variable values and engineering units to the blocks output channels. The ST100 process variables are

Flow, Temperature, Totalizer, and Pressure. Not all of these variables are available in all members of the ST100 family of products.

PRIMARY_VALUE parameter
This parameter makes available to the AI block the flow value of the ST100. Flow is organized into 3 classes; volumetric, mass, and velocity.

Each class has its associated valid engineering units. Confirm that units match the flow class.