Using the ST100 FF Service Transducer Block

Introduction to the Service Block
The ST100 Service Block provides viewing access to a number of parameters and the ability to read and write a number of other instrument

parameters through the Foundation Fieldbus Configurator tool.
This section is organized into three parts. The first part covers the instruments basic setup functions, the second part allows viewing of the instru-

ment Min and Max setting for the process variables, and the third part allows viewing of individual sensor head process parameters in a multi-

point system.

Basic Instrument Setup Functions
The basic setup functions include the ability to change and read engineering units for the process variable and the plenum. It also includes the

ability to read and change the value of the Plenum dimensions, and the ability to restore the factory calibration and setup values for the current

“Calibration Group”.

Review of Instrument Min / Max Settings
The Min/Max Setting Review allows you to read the instrument’s Flow Calibration maximum and minimum limits, the instrument’s Temperature

Calibration maximum and minimum limits and the Pressure Calibration minimum and maximum limits.