KT&C KVR-1601S User Manual

Page 57

Advertising
background image

57

 Please Click ( ) Alarm and the following screen will display.

 The Alarm menu allows a user to set Alarm based recording rates and resolution.
 Each box on Title column shows camera title registered in DEVICES>Camera. A user cannot change camera titles here.
 Click ( ) each box on Resolution column to select recording resolution of a corresponding camera. A user may select one of

360x240(288), 720x240(288), 720x480(576), 960x480(576), 1280x720 and 1920x1080.

 Click ( ) each box on Frames column to select recording rate of a corresponding camera. Recording rate varies by selected

recording resolution.

 Click ( ) each box on ‘Quality’ column to select recording quality of a corresponding camera. A user may select its recording

quality from Super, High, Standard and Low.

 Click ( ) each box on ‘Post Rec’ column to select recording duration (10 seconds ~ 10 minutes) of a corresponding camera.
 Click ( ) Drop-down list to change the setting values of Resolution, Frames, Quality and Post Rec. And If Click ( ) Drop-down

list of all frame, All items are changed at once

NOTE

E, F, G, H, I and J Type DVRs can detect 1080i, 1080p or 720p HD-SDI signals. If a user connects cameras before the booting, each
signal is automatically detected and recognized (Auto Detection).

CAUTION

IF A USER CONNECTS DIFFERENT TYPES OF HD-SDI SIGNALS WHILE DVR IS OPERATING. IT MAY CAUSE MALFUNCTIONS OF
DVR.

Record Camera

 Click ( )

to change the setting of Alarm in Record Camera and the following screen will display.

 A user can manually choose which cameras to record when Alarm In occurs.
 Please choose ‘OK’ to confirm the setting and choose ‘Cancel’ to cancel.

Alarm

Advertising