Chapter 6: RAID configuration

Rebuilding the RAID with new installed disk:

1. If one member of physical SATA Hard disk within the array is off-line or failed,

the status of array will become to be degraded from normal. The following

displays as.

2. Remove the failed SATA hard disk and install the same specification of new

SATA hard disk into the same SATA Port. After reboot, the rebuild will occur

automatically.

The size of new disk for rebuilding should be the same or bigger as the original

hard disk.

3. After selecting, the volumes with “Rebuild” status will be rebuilt within the

operating system.

4. Exit the SATA RAID utility. When the operating system is running, select the

Intel Matrix Storage Console from the Start Menu or click the Intel Matrix

Storage Manager tray icon.

5. From the View menu, select ‘Advanced Mode’ to display a detailed view of

the Intel Matrix Storage Console.

6. From the Volumes view in the device pane, select the RAID volume. The

status will display ‘Rebuilding % complete’. After the rebuild is complete, the

status will display ‘Normal’.