CTI Products RCD Advanced Client-Server User Manual

Page 28

Advertising
background image

Installation

28

68-11824-210

HW Setup – HIB-232 (non dial-up)

If you have a HIB-232 module (and are using it directly connected or through leased line modems) select
the proper COM port from the Possible Types list box:

The program detects all COM ports reported by Windows.
Not all may be available for use, depending on your PC.
Some COM ports may not be brought out to a connector.
Some COM ports may actually be used for an internal modem.

(In the example above, COM3 is actually an internal modem.)

USB to Serial Adapters

The MCN Server program will work with some USB to Serial adapters. We cannot guarantee that it will
work with all such adapters since we cannot test all brands.

Some USB to Serial adapters will change their COM port number when they are plugged into a different
USB connector. If you are using one of these and you change its connection, you will have to re-run the
HW Setup program to select the new COM port.

Select the proper COM Port and Click the Add NI button

Select the appropriate baud rate. Be sure that the baud rate matches the Baud rate switches on
the HIB-232 module.

(The Group and Module addresses for the HIB-232 unit are set with rotary switches

on the unit. See Important: MCN Address Setting on Page 26 for more information on MCN

addressing. )

Click the OK button.