November, 2003

455 D Control Panel Installation Instructions

When gate operator (1) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase.

When gate operator (1) reaches the positive
stop and the desired motor run time has been

reached, an open command must be given to

shut the motor off. At this point gate operator

(2) will automatically start to open.

When gate operator (2) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase.

When gate operator (2) reaches the positive
stop and the desired motor run time has been

reached, an open command must be given to

shut the motor off. At this point gate operator

(2) will automatically start to close.

When gate operator (2) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase.

When gate operator (2) reaches the positive
stop and the desired motor run time has been

reached, an open command must be given to

shut the motor off. At this point gate operator

(1) will automatically start to close.

When gate operator (1) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase.

When gate operator (1) reaches the positive
stop and the desired motor run time has been

reached, an open command must be given to

shut the motor off.

The display stops flashing and the gate is ready for

normal operation.

L

EARNING

T

IMES

WITH

G

ATECODER

Learning with the Gatecoder can be done in two

different ways:

S

IMPLE

L

EARNING

Close the gates, enter “Basic Programming”, select the

TIME LEARNING function and press the + push-button

for 1 second: the display begins flashing and the leaves

begin the opening movement.

The movement stops automatically when the opening

positive stop is reached and the display stops flashing.

The procedure has ended and the gate is ready to

operate, using default slow down automatically set by

the control panel.

L

EARNING

OF

O

PERATING

T

IMES

WARNING: During the learning procedure, the
safety devices are disabled! Therefore, any traffic

must be avoided in the path of the gate leaf(s).

NOTE: Must start with gate(s) in the closed
position.

Opening/closing time is established by the learning

procedure which varies slightly according to whether

you are or are not using Gatecoders.

L

EARNING

OF

N

ORMAL

T

IMES

Normal learning (i.e. without Gatecoders) can be done in

two different ways:

S

IMPLE

L

EARNING

Close the gates, enter “B

ASIC

P

ROGRAMMING

”, select the

TIME LEARNING function and press the + push-button

for 1 second the display begins flashing and the leaves

begin the opening movement.

Wait for the leaves to reach the opening positive stop

and then supply an OPEN A command after the desired

motor run time has been reached (by push-button or

radio control) to stop the movement: the leaves stop

and the display stops flashing. One more command

given will close the gate.

The procedure has ended and the gate is ready to

operate.

C

OMPLETE

L

EARNING

N

OTES

:

If you do not wish to slow the gate operator(s)
down, wait for the gate to reach its positive

stop and supply two (2) consecutive open

commands (within 1 second).

If only one gate operator (1) is used, you must
go through the entire programming procedure,

as if you were programming for two gate

operators (2). When the operator has finished

opening, supply 5 open commands until the

gate operator begins to close, and then resume

normal operations.

Close the gates, enter “B

ASIC

P

ROGRAMMING

”, select the

TIME LEARNING function and press the + push-button

for more than 3 seconds: the display begins flashing

and leaf 1 begins opening. The following functions can

be commanded by the OPEN A (by push-button wired to

terminals 9 and 14, or radio control):