Onnect, Ther, Evices – Controlled Products Systems Group 790919 User Manual

Page 4

Advertising
background image

Page

November, 2003

455 D Control Panel Installation Instructions

You cannot check the motor’s direction of rotation

without these circuits (jumpers) or the accessories.

When properly prepared for testing, the LEDS FSWOP,

STOP, and FSWCL should be illuminated (see figure 3.5

on page 5).

WARNING! Running the operator—even for testing
purposes—without a connected reversing device is

potentially dangerous. Do not place yourself within

the path of the moving gate during your test.

Disengage the operator(s) with the Manual Release key

(see operator installation manual), and open the gate by

hand about halfway.

Next, engage the operator(s) with the Manual Release

key so that you can check the rotation of the motor(s).

To activate the operator(s) momentarily short across

terminals 9 and 14.

Turn on the main power and send an activating signal to

the operator. The gate leaf (or leaves) should open. If a

gate leaf closes, then you need to turn off the main

power and reverse the connection of the red and black

wires on terminal block J4 for the operator controlling

that leaf. Then you need to recheck the rotation

direction again.

After having completed your test of the motor’s

direction of rotation, replace any test circuits you

installed (between terminals 11 and 16, between 12 and

19, and between 13 and 19) with the proper reversing

and stop devices. The instructions for installing such

accessories follow.

C

ONNECT

O

THER

D

EVICES

WARNING! Turn the main power off before you
make any electrical connections.

P

OWER

S

UPPLY

FOR

A

CCESSORIES

: You can access a 24 VDC

output for supplying power to accessories through

terminals 17 or 18, (+) and 14 or 15 or 16, (-) on

terminal block J1. In most cases, this source can be

used to power 24 VDC accessories.

N

OTE

: The 455 D control panel allows a maximum

accessory load of 800 mA.

R

EVERSING

D

EVICES

: Reversing devices include photocells,

inductive loops, and so forth. All of the reversing

devices should have contacts of the normally closed

(N.C.) type. Where you connect a device depends on

whether you want the device to operate during opening

or during closing.

N

OTE

: UL does not recognize the FAAC system

with loop detectors or safety edges. FAAC

photobeams must be used to comply with UL 325.

To wire photobeams, refer to page 4 (see FSWOP for

opening photobeams, and FSWCL for closing

photobeams). Photobeams must be connected as

shown. See also page 7 for the wiring of inductive loops.

If using more than one reversing device, they must be

wired in series.

A

CTIVATING

D

EVICES

AND

R

ADIO

R

ECEIVER

: The activating

devices and radio receiver for your gate must have

Figure 2.

The terminal strip wiring of the 455

D with photo-beams

NOTE: In order to comply with UL 325, two sets
of FAAC photobeams must be installed. One set
should be 6 in. outside the closed gate(s) and act
as a closing reversing device. Another set should
be 6 in. beyond the swing of the gate(s) and act
as an opening reversing device. The installer is
responsible for determining the appropriate
mounting height.

22 23 24 25

1

2

3

4

5

6

7

8

N

L

9

10 11 12 13 14 15 16 17 18 19

115 VAC +/- 10%

or

230 VAC +6/ -10%

50-60 Hz

20 21

-

STOP

OPEN

OPEN
(1 of 2)

24V

+

FSW

OP

CL

-

FSW

-

-

+

W.LIGHT

24 vdc

3 W

LOCK

ELECTRIC LOCK

1

2

1

2

3

4

5

1

2

3

4

5

1

2

FSWOP

FSWCL

Other safeties

LAMP

BL

U

E

MOTOR 1

C1

M1

OP

COM

CL

BL

U

E

MOTOR 2

C2

M2

OP

COM

CL

FOR WHEN THE FAAC

GATECODERS ARE USED

Advertising