Figure 4. common accessories wired to 455 d – Controlled Products Systems Group 790919 User Manual

Page 7

Advertising
background image

Magnetic Lock

Shadow Loop

Rev ersing Photocells

(f or closing)

3 & 4 Wire Radio Receiv ers

N.C.

N.O.

COM

N.C.

N.O.

COM

17

14

18

21

12 vac

Relay

+

-

Lock

12

19

7

8

NC

C

Coil Voltage =
Motor Voltage

Additional

Reversing Devices

17

14

9

NO

C

-

+

14

If 4 Wire Receiver

Free Exit Loop/ Phone/ Firebox

(Hold Open Dev ices)

14

9

C

NO

Rev ersing Photocells

(f or opening)

1

2

1

2

3

4

5

17

13

19

14

17

Additional

Reversing Devices

TX

RX

1

2

1

2

3

4

5

19

17

12

19

17

Additional

Reversing Devices

TX

RX

1

2

19

12

17

15

Additional

Reversing Devices

8

7

Saf ety Loop

Detector

(f or closing)

1

2

3

4

5

RX

19

17

12

14

17

TX

1

2

8

7

LOOP

DETECTOR

(FAAC)

Saf ety Series

Wiring

FAAC

FAAC

PHOTO-BEAMS

FAAC

FAAC

1

2

Page 7

November, 2003
455 D Control Panel Installation Instructions

NO = Normally Open, NC = Normally Closed, C = Common, TX = Transmitter, RX = Receiver

Figure 4. Common Accessories wired to 455 D

Advertising