Basic programming, Program buttons, Left middle right – Controlled Products Systems Group 790919 User Manual

Page 8

Advertising
background image

Page 8

November, 2003

455 D Control Panel Installation Instructions

P

ROGRAMMING

To program the automated system, the “Programming

Mode” must be accessed.

Programming is split into two parts: BASIC and

ADVANCED.

B

ASIC

P

ROGRAMMING

To access BASIC PROGRAMMING, press the “F” key.

If you press it (and hold it down), the display
shows the name of the first function.

If you release the key, the display shows the value
of the function that can be modified with keys +
and .

If you press and hold down the “F” key again (and
hold it down), the display shows the name of the

next function, etc.

When you reach the last function, press “F” to exit
the program, and the display resumes showing

the status of the inputs.

The table on the right shows the sequence of

functions accessible in BASIC PROGRAMMING.

A

DVANCED

P

ROGRAMMING

To access ADVANCED PROGRAMMING, press the “F”
key and, as you hold it down, press the “+” key:

If you release the “+”, the display indicates the
name of the first function.

If you release the “F” key, too, the display shows
the value of the function that can be modified

with keys “+” and “—”.

If you press the “F” key (and hold it down), the
display shows the name of the next function, and

if you release it, the value that can be modified

with keys “+” and “—”.

When you reach the last function, press the “F”
key to exit the program, and the display resumes

showing the status of the inputs.

The table on page 9 shows the sequence of functions

accessible in ADVANCED PROGRAMMING:

Display Function

Default

O

PERATING

L

OGICS

A = Automatic (Timer to Close)

E = Semi Automatic

S = Security

EP = (Semi-Automatic) Step by Step

B = Manned, Pulsed

C = Manned, constant

P

AUSE

T

IME

This is the time between open and

closing and is adjustable from 0 to

4 min. This is only true in “A”

Mode. (see pause time description)

F

ORCE

/T

ORQUE

M

OTOR

1

This adjusts the force / torque that

motor 1 is applying to the gate
leaf. Setting is 0 to 50.

*

F

ORCE

/T

ORQUE

M

OTOR

2

This adjusts the force / torque that

motor 2 is applying to the gate
leaf. Setting is 0 to 50.

*

C

LOSING

L

EAF

D

ELAY

Delays the closing of operator

wired into motor one outputs.

Adjustable from 0 to 4 minutes

(Same as pause time)

M

OTOR

R

UN

T

IME

This enables where you choose

from “simple” learning or

“complete” learning of the motor

run time. See page 10 & 11 for

complete details.

Simple Learning

~ 1 s.

Complete Learning

> 3 s.

E

XIT

P

ROGRAMMING

Exit from programming and return

to display of inputs status.

BASIC PROGRAMMING

+

F

+

PROGRAM BUTTONS

+ -

F

LEFT MIDDLE RIGHT

*

With Hydraulic operators the Force/Torque must be set to

the maximum setting of 50.

Advertising