Onnect, Perator, Ontrol – Controlled Products Systems Group 790919 User Manual

Page 3: Anel, Heck, Otor, Irection, Otation

Advertising
background image

RA

DI

O

1-455D115 = 115V

1-455D = 230V

F2

F1

M

M

K

+

OP

-

CL

+24 V

FSW

NC

-

B

-

STOP

A

+

TX

FSW

W. L.

LOCK

9

10 11 12 13 14 15 16 17 18 19

22 23 24 25

LAMP

COM OP

CL

MOTOR 1

MOTOR 2

CL

COM

OP

1

2

3

4

5

6

7

8

20 21

FC

A

1

FC

A

2

F

CC2

F

CC1

V1-4

61C455D

F

-

+

J2

J6

J4

J5

J1

J3

N

L

MAIN

Page 3

November, 2003
455 D Control Panel Installation Instructions

C

ONNECT

THE

O

PERATOR

(

S

)

TO

THE

C

ONTROL

P

ANEL


WARNING
!

Turn the main power off before you

make any electrical connections or before

programming.

C

AUTION

:

The operators are grounded only by

the grounded circuit the installer provides.

U

SING

A

J

UNCTION

B

OX

If an operator is more than 2 ft away from the control

panel, you must use a junction box for connection. Use

a U. L. Listed cord grip where the operator cord enters

the junction box.

Note: If you have a one-leaf gate design, the
operator must be connected to Motor 1 (terminals
1,2, & 3)

To wire up motor 1, connect the white wire to terminal

1(on the J4 terminal strip), the black wire to 2, and the

red wire to 3. Wire each leg of the capacitor (supplied)

to terminals 2 & 3.

Note: If you want to delay the closing of one gate
leaf in a two-leaf gate design, be sure to connect

its operator to Motor 1.

In order to wire motor 2 in a bi-parting system, connect

the white wire to terminal 4 (on the J4 terminal strip),

the black wire to 5, the red wire to 6. Wire each leg of

the capacitor (supplied) to terminals 5 & 6.

C

HECK

THE

M

OTOR

S

D

IRECTION

OF

R

OTATION

After you have connected the main power supply, and

the operator(s) to the control panel, you need to check

the direction of rotation for each operator motor in your

gate design.

Note: To check a motor’s direction of rotation,
you must have three closed circuits on terminal

block J1. Install one circuit between terminals 11

and 16, another circuit between terminals 12 and

19, and another circuit between terminals 13 and

19.

Figure 1. The 455 D Control Panel

J3

terminal block for main

power supply

J4

terminal block for

connecting the operator(s)

J1

terminal block for low-

voltage accessories

J2

quick connector port

F

Function Push Button

Programming Push

Button

+

Programming Push

Button

FUSES

220

VAC

115

VAC

F1

Main Power

5 A

10 A

F2

A

ccessories

800

mA

800

mA

Advertising