November, 2003
455 D Control Panel Installation Instructions

C

OMPLETE

L

EARNING

N

OTES

:

If only one gate operator (1) is used, you
must go through the entire programming

procedure, as if you were programming a

gate operator (2). When the gate operator

(1) has finished opening, supply 5 open

commands until the gate operator begins to

close, and then resume normal operations.

Close the gates, enter “B

ASIC

P

ROGRAMMING

, select the

TIME LEARNING function and press the + push-button

for more than 3 seconds: the display begins flashing

and leaf 1 begins opening movement. The following

functions can be commanded by the OPEN A

command (by radio control or key push-button):

When gate operator (1) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase. When the gate operator

reaches its positive stop, the operator will

automatically shut off.

An open command must be given to start
opening gate operator (2).

When gate operator (2) reaches the position
that you want it to slow down, an open

command must be given to start the slow

down phase. When the gate operator

reaches its positive stop, the operator will

automatically shut off.

An open command must be given to start
closing gate operator (2).

When gate operator (2) reaches the position that
you want it to slow down, an open command must

be given to start the slow down phase. When the

gate operator reaches its positive stop, the

operator will automatically shut off.

An open command must be given to start closing
gate operator (1).

When gate operator (1) reaches the position that
you want it to slow down, an open command must

be given to start the slow down phase. When the

gate operator reaches its positive stop, the

operator will automatically shut off.

The display stops flashing and the gate is ready for normal

operation.

N

OTES

:

The open command to slow down the gate should
be given before the gate reaches the positive stop

to prevent the gate from hitting the stop at full

speed. The positive stop could be mistaken for an

obstacle and then upon hitting it, the gate(s) would

automatically reverse on contact.

A

UTOMATED

S

YSTEM

T

EST

When you have finished programming, check if the system is

operating correctly.

Most important of all, check that the force is adequately

adjusted and that the safety devices are operating correctly.

If pressure adjustments on hydraulic operators are not set

before programming. It may need to be reprogrammed for

desired results.