November, 2003
455 D Control Panel Installation Instructions

normally open (N.O.) contacts. Connect such devices to

terminals 9 and 14.

N

OTE

: The FAAC radio receiver plugs into the 5

prongs labeled J2 (Quick connect port).

Page 7 shows how to connect a three or four wire

receiver.

D

ECODER

C

ARD

: If you are installing the Digicard

magnetic card reader, or the Digikey keyboard, use the

quick-fit connector J2 for the DS decoder card (see

Figure 1).

N

OTE

: If your using both a receiver and decoder,

hard wire the decoder and plug in the receiver.

O

PEN

/H

OLD

O

PEN

D

EVICE

: To open and hold open the

gate, simply maintain a contact across terminals 9 and

14. (“A” Mode only)

S

TOP

B

UTTON

: The stop button you install must have

normally closed (N.C.) contacts. Multiple

stop buttons must be wired in series. Connect your stop

device between terminals 11 and 16.

N

OTE

: The 455 will not operate the motors without

a closed circuit between 11 & 16.

The LED Indicators: The nine light emitting diodes
(LEDs) on the control panel can be used to check for the

proper function of the devices attached to the panel.

The LED lights are on whenever the contacts are closed

across each of the respective terminals.

OP_A and OP_B (Partial Opening) should illuminate only

when an activating signal is sent for 2 and 1 gate leaves,

respectively. STOP should be illuminated except when

the stop button is pressed. FSWOP and FSWCL should be

illuminated except when the reversing devices, for

Figure 3.

Wiring detail (a)

inside the junction

box and (b) from the

junction box or

operator to the high-

voltage terminal strip

on the 455 D control

panel

F S W O P

F S W C L

O P _ A

O P _ B

S T O P

F C A 1

F C A 2

F C C 1

F C C 2

LED

On

Off

OP_A

Command Given

No Command

OP_B

Command Given

No Command

Stop

No Command

Command Given

FSW

Open

Opening reversing

devices clear

Reversing device

triggered

FSW

Close

Closing reversing

devices clear

Reversing device

triggered

FCA1

FCC1

Flashes when gate coder is in use.

Operator 1

FCA 2

FCC 2

Flashes when gate coder is in use.

Operator 2

FSWOP

FSWCL

OP_A

OP_B

STOP

FCA1

FCA2

FCC1

FCC2

This display shows the normal

status of the control panel.

This display shows the
meaning of each LED.

U.L. Listed Control Panel Enclosure

Cord grip or

conduit from

U.L. Listed gate

operator(s)

(b)

Op.1

Op.2

COM OP CL COM OP CL

J3

J4

High-voltage

terminal strip

455 MPS Control Panel

Ground

J1

To the U. L. Listed

gate operator

To the U.L. Listed

control panel

U.L. Listed

cord grip

Junction box

Legend

White

Red

Black

Yellow/
Green

(a)

Conduit to U.L. Listed

control panel enclosure

according to N.E.C.

Figure 3.5 The 455 D display.