Pach and Company AeGIS 4000P Manual User Manual

Page 17

Advertising
background image

01-20

INDIVIDUAL

ACCESS CODE

TO ACCESS

RELAY 1

(DOOR 1)

21-40

INDIVIDUAL

ACCESS CODE

TO ACCESS

RELAY 2

(DOOR 2)

41-50

INDIVIDUAL

ACCESS CODE

TO ACCESS

BOTH RELAY 1

AND 2 (DOOR 1

AND DOOR 2)

Step 3

Enter 00 then #, you will

hear “No Beep”.

Step 4

Enter new 4-digit Master

Code then press # then you will hear
“One Short Beep” and proceed to
step 5 or if you decided
not to change the existing Master
Code press

∗ to exit and you will hear

“Three Short Beeps”.

Step 5

Continue to program another

parameter or press

∗ to exit; you will

hear “Three Short Beeps”.

Step 1

Entering The Programming

Mode: Press 0 and # simultaneously
then release.
If you are in the pro-
gramming mode, proceed to step 2.

Step 2

Enter the 4-digit Master

Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see section
Reset Master Code.

Step 3

Enter the Index Number

(01 – 20, 21-40 or 41-50) then #, you
will hear “No Beep”. If the associated
Index Number has an access code
programmed, you will hear “Two Long
Beeps”.
Press

∗, you will hear “One

Short Beep” and select another Index
Number.

Step 4

Enter the 4-digit access

code then #, you will hear “One
Beep”.

Do not program the same code as in
index01-20, 21-40 and 41-50, doing
so the access code programmed
won’t work.

Step 5

Return to step 3 to program

another access code or enter another
Function Code to program another
parameter, otherwise
press

∗ to exit and you will hear

“Three Short Beeps

Step 1

Pick up the phone and wait

for dial tone.

Step 2

Press # # and you will hear

“One Short Beep”.

Step 3

Press # and you will hear

“One Short Beep”.

Step 4

Enter the 01-20, 20-21 or

41-50) then press #, you will hear “No
Beep”
: the index numbers is empty
and proceed to Step 5. “Two Long
Beeps”
: the index number is not
empty and you must do one of the
following:
• Press 1 then # you will hear “No

Beep” to overwrite existing access
code and proceed to Step 4.

• Press

∗ ∗ you will “One Short Beep”

and repeat this step.

Step 5

Enter the 4-digit access

code number then press #, you will
hear “One Short Beep”.

Do not program the same code as in
index 01-20, 21-40 and 41-50, doing
so the access code programmed
won’t work.

Step 6

Return to step 4 to program

another access code or enter another
function code to program different
parameter or exit the
program by pressing

∗ ∗ and you will

hear “Three Short Beeps”.

Pach and Company

Page 9

AeGIS 4000P

Chapter 3. Programming

Step 1

Call to the AeGIS 4000P

system (you must know the system’s
phone number), you will hear: “One
Short Beep”,
the gate is locked. “Two
Short Beeps”,
the gate is unlocked.

Step 2

Press # then enter a valid

master code and you will hear:
“One Short Beep”, the master code
is accepted then press # and you will
hear “One Short Beep” .
“One Long Beep”, the master code
is rejected and the connection will be
disconnected.

Step 3

Press # to enter into the pro-

gramming mode and you will hear
“One Short Beep” or

∗∗ to hang-up

the call.

Step 4

Enter the 01-20, 21-40, or

41-50then press #, you will hear “No
Beep”
: the index numbers is empty
and proceed to Step 5. “Two Long
Beeps”
: the index number is not
empty and you must do one of the
following:
• Press 1 then # you will hear “No

Beep” to overwrite existing access
code and proceed to Step 4.

• Press

∗ ∗ you will “One Short Beep”

and repeat this step.

Step 5

Enter the 4-digit access

code number then press #, you will
hear “One Short Beep”.

Do not program the same code as in
index 01-20, 21-40 and 41-50, doing
so the access code programmed
won’t work.

Step 6

Return to step 4 to program

another access code or enter another
function code to program different
parameter or exit the
program by pressing

∗ ∗ and you will

hear “Three Short Beeps”.

Function

Local Programming

Premise Phone

Remote Phone

Program

Individual

Access Code

Advertising