ADIC Scalar Series User Manual

Page 36

Advertising
background image

26

Equipment Description

Set SCSI ID

Lets you select the SCSI ID for the robotics on the library.

p Use UP and DOWN to select the desired ID. Press ENTER to execute the change. Confirm the change by

pressing ENTER again.

Product Sign-On

Lets you select how the Scalar Library appears to application software. The library can be set to sign-on as an

Exabyte

®

EXB-480

library. This permits maximum application software compatibility.

p Use UP or DOWN to select “Y” or “N”. Press ENTER to execute the change.

Note

Product Sign-On default is EXB-480: N.

Off-Line Time

Lets you set the number of minutes the Scalar Library will remain in the Off-Line Mode. If someone leaves the
library in the Off-Line mode, after the pre-set number of minutes the library will automatically return to the On-
Line Mode. This assures that your automatic backup will be done even if the library has accidentally been left off-
line.

Note

Off-Line Time default setting is "5" minutes.

p Use UP or DOWN to select the number of minutes you wish the Scalar Library to remain in Off-Line Mode.

Press ENTER to execute the change.

Advertising