ADIC Scalar Series User Manual

Page 68

Advertising
background image

58

Diagnostics Menu

rr

=

Row number (01 - 2)

dd

=

Drive number (01 - 04)

This function is usually used for diagnostics only by a trained technician.

Place In Slot

The Place In Slot function will cause the Media Picker to place the cartridge into a storage slot.

p Use LEFT or RIGHT to select the desired field. Select the row and slot using UP or DOWN. Press ENTER

to activate.

rr

=

Row number (01 - 04)

ss

=

Slot number (01 - 12)

This function is usually used for diagnostics only by a trained technician.

Place In Mailbox (when Mailbox equipped)

The Place In Mailbox function will cause the Media Picker to place the cartridge into a Mailbox slot.

p Use LEFT or RIGHT to select the desired field. Select the MB row and slot using UP or DOWN. Press

ENTER to activate.

rr

=

Row number (01 - 2)

ss

=

Slot number (01 - 05)

This function is usually used for diagnostics only by a trained technician.

Place In Drive

The Place In Drive function will cause the drive door to open and the Media Picker to place the cartridge into the
drive.

Advertising